I spent quite some time troubleshooting what should have been a simple addition to my four-port KVM: connecting a laptop wirelessly using a UGREEN HDMI kit.
The problem was surprisingly subtle. The desk monitor could show a perfectly usable picture while the KVM’s web interface reported “No HDMI signal detected” and displayed 0 frames per second. Changing EDID profiles would fix one device and break another.
The breakthrough came when I discovered that the Comet X capture driver rejected HDMI active resolutions whose width or height was not divisible by four. Windows was drawing a 1680×1048 desktop, but actually transmitting 1680×1050 over HDMI.
TL;DR: The two extra lines explained the wired capture failure. An ASUS-derived EDID with an optional 1680×1048 timing, together with a source-side Windows investigation, restored browser access to the wired computers and allowed the wireless laptop to work on port 4. The wireless feed was observed at 1280×720.
The KVM was a GL.iNet Comet X (GL-RM4PE), running firmware V1.10.1 release4. Three computers were connected directly over HDMI; a UGREEN wireless HDMI transmitter and receiver connected the fourth.
The Comet has two distinct ways of showing the selected computer:
Local display: the HDMI OUT port sends the selected picture to the physical monitor.
Remote display: the HDMI capture pipeline acquires the picture, encodes it as H.264 and streams it to the browser via WebRTC.
Figure 1. The monitor and browser use the same selected source, but only the browser depends on the capture pipeline.
This distinction is central to the investigation. A working physical monitor does not necessarily mean that the remote capture pipeline can acquire the same signal.
Both devices had previously worked in other combinations: the UGREEN kit with an iPhone and projector, and the Comet with a wired iPhone HDMI connection. The issue appeared when combining the wireless receiver, the KVM and the display profiles used by my computers.
2. The real clue: a two-pixel difference
With the web interface showing 0 fps, I checked the Comet’s logs. The same two messages kept appearing:
gsv1127x_rcv_supported_res: width and height must be divisible by 4
gsv1127x_get_detected_timings: rcv err res, return no signal!
The capture driver was explicitly rejecting an active resolution whose dimensions were not multiples of four. Without captured frames, neither the H.264 encoder nor WebRTC could produce a picture.
Active resolution
Divisible by 4?
Capture dimension check
1680×1050
No: 1050 leaves remainder 2
Fails
1680×1048
Yes
Passes
1920×1080
Yes
Passes
1280×720
Yes
Passes
Important: Passing this check does not guarantee a working HDMI signal. Several 1080p profiles still failed in testing. The dimension restriction explains the 1050-line rejection, not every wireless or EDID compatibility issue.
That is why adjusting browser quality or WebRTC settings was not the right starting point. The failure was upstream, at HDMI acquisition.
3. Why a simple EDID change was not enough
EDID (Extended Display Identification Data) tells a source which resolutions and timings a display supports. In this setup, the Comet advertised the display capabilities to the connected devices.
Unfortunately, a profile that worked for the wired computers did not necessarily work for the wireless receiver.
EDID profile
Web capture
UGREEN wireless
Original custom timing
Worked
Failed
Factory ASUS 1080p60
Failed in this test
Worked
Custom 720p60 RGB
Worked
Worked
Custom 1600×900
Worked
Worked
Final ASUS-derived hybrid
Worked after local investigation
Worked; 720p observed
The 720p and 1600×900 profiles proved that the two paths could coexist, but the desktop resolution was lower than I wanted. Lower refresh rates and reduced blanking did not provide a complete solution either.
Interestingly, standard 720p60 and 1080p30 timings share a 74.25 MHz pixel clock. The former worked and the latter failed in web capture. Without measuring the actual signal on the wire, this was not proof of a chipset limit, but it was a good reason to stop treating the pixel clock as the only variable.
Instead of forcing every device to use the same resolution, I built a hybrid EDID based on the factory ASUS profile. It retained the standard HDMI modes and added the previously tested 1680×1048 timing.
EDID component
Purpose
Base block (128 bytes)
ASUS ROG PG248Q identity; preferred 1920×1080 at 60 Hz
CTA extension (128 bytes)
Standard HDMI video modes, audio/HDMI data and optional 1680×1048 detailed timing
The preferred 1080p mode remained available for sources that wanted a familiar HDMI timing. The optional 1680×1048 mode gave the wired computers an alternative compatible with the capture driver’s dimension check.
With port 4 selected, the wireless laptop appeared in the Comet web interface at 1280×720. The preferred mode advertised by the EDID was 1920×1080, but that is not necessarily the resolution ultimately delivered to the capture pipeline. I did not establish where 720p was selected or whether the UGREEN kit scaled the picture.
5. Windows: desktop mode is not active signal mode
One Lenovo laptop still failed after applying the hybrid EDID. This turned out to be the most useful Windows-specific finding of the entire investigation.
Under Settings → System → Display → Advanced display, Windows reported two different resolutions for the external display:
Windows setting
Reported value
Desktop mode (what Windows renders)
1680×1048
Active signal mode (what HDMI transmits)
1680×1050
Why it matters: The desktop had already been changed to 1048 lines, but the display driver was still transmitting 1050. The Comet validates the incoming signal, not the size of the Windows desktop.
Identify the GPU that actually controls HDMI
The laptop contained both an Intel HD Graphics 4600 and an NVIDIA GeForce 840M. However, Advanced display identified Intel as the relevant adapter, and the NVIDIA Control Panel had no Display category. Troubleshooting NVIDIA’s display service was therefore not a substitute for checking the actual HDMI output path.
I used Custom Resolution Utility (CRU) to add a persistent local EDID override. It made 1680×1048 available as a desktop mode, but initially did not change the active signal. The global Comet EDID and the local Windows override were separate configuration layers.
Verify the installed display driver
The first Intel driver installation appeared to succeed, but Windows still reported version 20.19.15.4531. The intended 20.19.15.5171 package was absent from the Driver Store.
These PowerShell commands distinguish the version associated with each graphics adapter from the packages available in the Driver Store:
Get-CimInstance Win32_VideoController |
Select-Object Name, DriverVersion
# Run in an elevated PowerShell window to inspect the online driver store.
Get-WindowsDriver -Online |
Where-Object { $_.ClassName -eq "Display" } |
Format-Table Driver, ProviderName, Version, Date -AutoSize
Web capture recovered after retrying the Intel installation. I did not retain a final driver-version listing or active-signal screenshot, so I cannot conclusively attribute recovery to one particular installer action or confirm the final transmitted timing.
Wireless and browser capture working; 1280×720 observed
The desired combination was achieved in everyday use: all three wired computers accessible remotely, plus the wireless laptop on port 4. I did not document a four-port cold-start acceptance test or independently measure the wireless transmission format.
7. How I would troubleshoot this next time
Separate the symptoms. Check the desk monitor, browser capture and wireless connection independently.
Inspect the KVM logs. If the browser reports 0 fps, look for HDMI capture errors before adjusting stream quality.
Check the active signal. In Windows, compare desktop mode with active signal mode on the external display.
Start with a known working timing. Establish a standard-mode baseline before building custom EDIDs.
Verify the relevant driver. Identify the adapter that owns the HDMI output and check both active driver and Driver Store versions.
Retest after switching ports. An immediate success may disappear after HDMI renegotiation. Repeat after a restart if practical.
Also, save the original EDID before editing it. If the source is the same computer that runs the browser, avoid clicking the remote canvas while changing ports: the input can be sent straight back to that computer.
The lesson: a monitor displaying a picture and a KVM successfully capturing that picture are different things. A difference of just two active lines was enough to make one path work and the other fail.
Technical appendix: reproduce the configuration
The following details are for anyone investigating a similar Comet X setup or reproducing the exact profile.
A. The 1680×1048 detailed timing
The detailed timing descriptor begins with 21 39, representing a 146.25 MHz pixel clock (little-endian, in units of 10 kHz).
The existing descriptor was preserved rather than regenerated, because specifying only a resolution and nominal refresh rate does not uniquely determine the timings. The preferred 1080p60 mode uses 148.50 MHz and totals of 2200×1125.
The CTA extension retains video identification codes (VICs) 16, 31, 4, 19, 3, 18 and 1: the 1080p60, 1080p50, 720p60, 720p50, 480p60, 576p50 and 640×480p60 families. VIC 16 remains flagged as native.
B. Exact hybrid EDID (256 bytes)
In the Comet web interface, go to Session Settings → Video → EDID → Customize → Edit. Save the existing EDID or factory preset, paste these hex bytes and select Set Custom.
The base and extension checksum bytes are 99 and fc. To verify the profile, save the hex rows in comet-edid.txt and hash the decoded bytes, not the textual representation:
from hashlib import sha256
from pathlib import Path
raw = bytes.fromhex(Path("comet-edid.txt").read_text(encoding="utf-8-sig"))
assert len(raw) == 256
assert raw[126] == 1 # One extension follows the base block.
assert sum(raw[:128]) % 256 == 0
assert sum(raw[128:]) % 256 == 0
print(sha256(raw).hexdigest())
A valid checksum verifies copying integrity, not hardware compatibility. Keep a working fallback before applying the profile to another setup.
C. Full experiment log
Expand all tested EDID combinations
Profile or change
Web capture
UGREEN / interpretation
Original custom detailed timing
Worked
Wireless failed. Useful wired reference.
Factory ASUS 1920×1080/60
Failed in this test
Wireless worked. Useful wireless reference.
Custom 1080p60 RGB
No complete success
Wireless result unconfirmed.
Custom 720p60 RGB
Worked
Wireless also worked. Useful low-resolution control.
Custom 1080p30, then 1080p50
Failed in both tests
Wireless result unconfirmed. Lowering the refresh rate alone did not solve it.
Custom 1600×900
Worked
Wireless also worked. Desktop detail was below the goal.
1080p reduced blanking, then 1680×1050 reduced blanking
Failed in both tests
Changing blanking alone did not produce the combination we needed.
Original custom profile plus CTA VIC 16
Worked
Wireless failed after an initially promising result.
Custom base with ASUS extension
Unconfirmed
Wireless failed.
ASUS base with earlier custom extension
Eventually failed
Wireless worked. Both had appeared to work initially.
Factory GSV profile for a different model / another VIC 16 hybrid
No verified outcome
Neither established a working baseline.
Saved ASUS-derived profile plus optional 1680×1048 timing
Web capture observed
Port 4 also worked wirelessly. One Windows machine still needed local attention.
D. Test notes and limitations
The saved web baseline used Direct H.264, Normal mode, Smooth Display, High quality, 0° orientation and Adaptive view. Adaptive view scales the image in the browser, so the apparent picture size is not a measurement of captured resolution.
The EDID backup and port checks were taken at different times. Port 1 showed 0 fps in an earlier snapshot; port 3 was the last outstanding wired failure in the later investigation. These are separate observations rather than contradictory results from a single test.
For a repeatable test, record the source, physical picture, wireless picture, browser picture and fps, desktop mode, active signal mode, EDID hash and whether the port was freshly selected. The final Windows timing and wireless radio format were not independently verified.
Mr. Menelaos Bakopoulos is currently pursuing his PhD both at Center for TeleInFrastruktur (CTiF) at Aalborg University (AAU) in Denmark and Athens Information Technology (AIT) in Athens, Greece. He received a Master in Information Technology and Telecommunications Systems from Athens Information Technology and a B.Sc. in Computer Science & Management Information Systems from the American College of Thessaloniki. Since April 2008 he has been a member of the Multimedia, Knowledge, and Web Technologies Group.
This blog is related to topics about operating systems, development, coding, and software and
contains our own opinions, code, and examples unless otherwise stated.
It is also a work in progress - so bear with us as we improve the template and content.
Nov 27 2026
Why two pixels mattered on a GL.iNet Comet X with UGREEN wireless HDMI
I spent quite some time troubleshooting what should have been a simple addition to my four-port KVM: connecting a laptop wirelessly using a UGREEN HDMI kit.
The problem was surprisingly subtle. The desk monitor could show a perfectly usable picture while the KVM’s web interface reported “No HDMI signal detected” and displayed 0 frames per second. Changing EDID profiles would fix one device and break another.
The breakthrough came when I discovered that the Comet X capture driver rejected HDMI active resolutions whose width or height was not divisible by four. Windows was drawing a 1680×1048 desktop, but actually transmitting 1680×1050 over HDMI.
In this article: Setup · Root cause · EDID solution · Windows fix · Results · Technical appendix
1. The setup: four computers, two video paths
The KVM was a GL.iNet Comet X (GL-RM4PE), running firmware V1.10.1 release4. Three computers were connected directly over HDMI; a UGREEN wireless HDMI transmitter and receiver connected the fourth.
The Comet has two distinct ways of showing the selected computer:
This distinction is central to the investigation. A working physical monitor does not necessarily mean that the remote capture pipeline can acquire the same signal.
Both devices had previously worked in other combinations: the UGREEN kit with an iPhone and projector, and the Comet with a wired iPhone HDMI connection. The issue appeared when combining the wireless receiver, the KVM and the display profiles used by my computers.
2. The real clue: a two-pixel difference
With the web interface showing 0 fps, I checked the Comet’s logs. The same two messages kept appearing:
The capture driver was explicitly rejecting an active resolution whose dimensions were not multiples of four. Without captured frames, neither the H.264 encoder nor WebRTC could produce a picture.
That is why adjusting browser quality or WebRTC settings was not the right starting point. The failure was upstream, at HDMI acquisition.
3. Why a simple EDID change was not enough
EDID (Extended Display Identification Data) tells a source which resolutions and timings a display supports. In this setup, the Comet advertised the display capabilities to the connected devices.
Unfortunately, a profile that worked for the wired computers did not necessarily work for the wireless receiver.
The 720p and 1600×900 profiles proved that the two paths could coexist, but the desktop resolution was lower than I wanted. Lower refresh rates and reduced blanking did not provide a complete solution either.
Interestingly, standard 720p60 and 1080p30 timings share a 74.25 MHz pixel clock. The former worked and the latter failed in web capture. Without measuring the actual signal on the wire, this was not proof of a chipset limit, but it was a good reason to stop treating the pixel clock as the only variable.
The full experiment log is in the appendix.
4. The solution: one EDID with two useful options
Instead of forcing every device to use the same resolution, I built a hybrid EDID based on the factory ASUS profile. It retained the standard HDMI modes and added the previously tested 1680×1048 timing.
The preferred 1080p mode remained available for sources that wanted a familiar HDMI timing. The optional 1680×1048 mode gave the wired computers an alternative compatible with the capture driver’s dimension check.
With port 4 selected, the wireless laptop appeared in the Comet web interface at 1280×720. The preferred mode advertised by the EDID was 1920×1080, but that is not necessarily the resolution ultimately delivered to the capture pipeline. I did not establish where 720p was selected or whether the UGREEN kit scaled the picture.
The exact 256-byte profile and detailed timing are included below for reproduction.
5. Windows: desktop mode is not active signal mode
One Lenovo laptop still failed after applying the hybrid EDID. This turned out to be the most useful Windows-specific finding of the entire investigation.
Under Settings → System → Display → Advanced display, Windows reported two different resolutions for the external display:
Identify the GPU that actually controls HDMI
The laptop contained both an Intel HD Graphics 4600 and an NVIDIA GeForce 840M. However, Advanced display identified Intel as the relevant adapter, and the NVIDIA Control Panel had no Display category. Troubleshooting NVIDIA’s display service was therefore not a substitute for checking the actual HDMI output path.
I used Custom Resolution Utility (CRU) to add a persistent local EDID override. It made 1680×1048 available as a desktop mode, but initially did not change the active signal. The global Comet EDID and the local Windows override were separate configuration layers.
Verify the installed display driver
The first Intel driver installation appeared to succeed, but Windows still reported version
20.19.15.4531. The intended20.19.15.5171package was absent from the Driver Store.These PowerShell commands distinguish the version associated with each graphics adapter from the packages available in the Driver Store:
Web capture recovered after retrying the Intel installation. I did not retain a final driver-version listing or active-signal screenshot, so I cannot conclusively attribute recovery to one particular installer action or confirm the final transmitted timing.
Related reference: Microsoft’s documentation on overriding monitor EDIDs.
6. Final results
The desired combination was achieved in everyday use: all three wired computers accessible remotely, plus the wireless laptop on port 4. I did not document a four-port cold-start acceptance test or independently measure the wireless transmission format.
7. How I would troubleshoot this next time
Also, save the original EDID before editing it. If the source is the same computer that runs the browser, avoid clicking the remote canvas while changing ports: the input can be sent straight back to that computer.
The lesson: a monitor displaying a picture and a KVM successfully capturing that picture are different things. A difference of just two active lines was enough to make one path work and the other fail.
Technical appendix: reproduce the configuration
The following details are for anyone investigating a similar Comet X setup or reproducing the exact profile.
A. The 1680×1048 detailed timing
The detailed timing descriptor begins with
21 39, representing a 146.25 MHz pixel clock (little-endian, in units of 10 kHz).The existing descriptor was preserved rather than regenerated, because specifying only a resolution and nominal refresh rate does not uniquely determine the timings. The preferred 1080p60 mode uses 148.50 MHz and totals of 2200×1125.
The CTA extension retains video identification codes (VICs) 16, 31, 4, 19, 3, 18 and 1: the 1080p60, 1080p50, 720p60, 720p50, 480p60, 576p50 and 640×480p60 families. VIC 16 remains flagged as native.
B. Exact hybrid EDID (256 bytes)
In the Comet web interface, go to Session Settings → Video → EDID → Customize → Edit. Save the existing EDID or factory preset, paste these hex bytes and select Set Custom.
The base and extension checksum bytes are
99andfc. To verify the profile, save the hex rows incomet-edid.txtand hash the decoded bytes, not the textual representation:Expected SHA-256:
A valid checksum verifies copying integrity, not hardware compatibility. Keep a working fallback before applying the profile to another setup.
C. Full experiment log
Expand all tested EDID combinations
D. Test notes and limitations
The saved web baseline used Direct H.264, Normal mode, Smooth Display, High quality, 0° orientation and Adaptive view. Adaptive view scales the image in the browser, so the apparent picture size is not a measurement of captured resolution.
The EDID backup and port checks were taken at different times. Port 1 showed 0 fps in an earlier snapshot; port 3 was the last outstanding wired failure in the later investigation. These are separate observations rather than contradictory results from a single test.
For a repeatable test, record the source, physical picture, wireless picture, browser picture and fps, desktop mode, active signal mode, EDID hash and whether the port was freshly selected. The final Windows timing and wireless radio format were not independently verified.
Menelaos Bakopoulos
Mr. Menelaos Bakopoulos is currently pursuing his PhD both at Center for TeleInFrastruktur (CTiF) at Aalborg University (AAU) in Denmark and Athens Information Technology (AIT) in Athens, Greece. He received a Master in Information Technology and Telecommunications Systems from Athens Information Technology and a B.Sc. in Computer Science & Management Information Systems from the American College of Thessaloniki. Since April 2008 he has been a member of the Multimedia, Knowledge, and Web Technologies Group.